Surface Cleanliness

View:

Sandblasting salt content determination group 138A

● Meets ASTM D4940 specifications
● 1 x Elcometer 138E conductivity meter
● Contains 1 x 1413 μS/cm (1.413 mS/cm) calibration solution 20ml (0.74 fl oz)
● 1 bottle of distilled water 1000ml (33.8 fl oz)
● 2 glass beakers with 100ml (3.4 fl oz) and 600ml (20.3 fl oz)
● Includes 1 plastic measuring cup 500ml (16.9 lf oz)
● 1 funnel
● 1 stirring rod
● With filter paper x 100 (piece)
● LR44 alkaline battery, carrying case, operating instructions

Salt contamination tester 130

● The salt contamination tester is simple and fast.
● Battery operation.
● Keep dry test strips to reproduce test results.
● High accuracy.

Bresle Finishing Patch 135A

● Bresle surface clean test piece is a self-adhesive rubber patch.
● After the test piece is attached to the surface to be tested, the pure water is injected into the syringe with a flow of about 1.5~2cc, so that the soluble surface molecules are dissolved in the injected water, and then the injected water is sucked out, and then tested by the test paper. The precipitate in the water was sampled.

Bresle Surface Cleanness Test Set 138-2

● The surface cleanness test group can measure the degree of surface contamination to be coated. The higher the cleanliness of the surface before construction, the more the life of the protected layer after construction can be ensured. If the cleanliness beforehand is not tested according to the standard, it will take more time and cost to re-construct or repair in the future.
● The Elcometer 138/2 is a low-cost, easy-to-use device.
● Elcometer 138/2 measures surface salt, pH, iron ions, and chloride ions.
● After the test piece is attached to the surface to be tested, the pure water is injected into the syringe with a flow of about 1.5~2cc, so that the soluble surface molecules are dissolved in the injected water, and then the injected water is sucked out, and then tested by the test paper. The precipitate in the water was sampled.
● Compliance with ISO.

Steel surface dust measurement group 142

● The steel surface sand dust measurement group can quickly evaluate the amount of sand dust and the size of sand dust particles before surface coating construction.
● The dust contained in the surface of the coating will cause poor adhesion of the coating and shorten the life.
● Test results can be placed in a report and saved permanently.
● The carrying case is suitable for on-site use.
● Contains sand and dust comparison pictures as a basis for comparison.
● Evaluate the work plate to ensure that the sand dust is not in contact with the environment.
● The record sheet is available for immediate recording by the user.

Chloride ion determination group in water 134w

● The chloride ion determination group in water is used to measure the chloride ion content of high pressure water.

Amine-based coating amine water detection 139

● Amine based coating amine water detection is simple and easy to use.
● Provide on-site quick testing.

Bresle steel surface finish test group 138

● The steel surface finish test group measures the degree of surface contamination to be applied.
• Use a conductivity meter to determine the extent of surface contamination.
● Surface contamination includes: oil dust, chloride and so on.
● Determine the chloride ion content based on conductivity.
● Compliance with ISO.

Steel surface salt analyzer 134s

● The steel surface salt meter is easy to use.
● Provide on-site quick testing.
● Compliance with ISO.

Chloride ion content analyzer 134a

● The chloride ion analyzer is easy to use.
● Provide on-site quick testing.
● Compliance with ISO, BS.

Chloride sulfate nitride test group 134

● The chloride, sulfate, and nitride test groups are pre-adjusted to give the correct results.
● Results are expressed directly in PPM without complex calculations.
● Compliance with ISO, NACE, SSPC.
© 2019 TWOSOME TRADING CORP. All rights reserved.